| Supply | 12-240V dc/24-240V ac |
| Output | SPCO Relay 3A 240V max. Non-inductive |
| Output State | Output energised (ON) at set running speed, de-energises if rotation falls by 20% or more below set speed |
| Operating Range | 12mm |
| Hysterisis | 15% of operating range |
| Calibration | Start-up delay & set running speed, user programmable using magnet (supplied) applied to target area on sensor body. Automatically calibrates to 20% under normal running speed-15 |
| Start-up Delay | Programmable start-up delay. Output energises for time period irrespective of incoming pulse signal, allows machinery to achieve normal running speed. Max 30 second delay |
| AmbientTemperature | -15°C to +50°C |
| IP Rating | IP65 |
| Enclosure | Nylon 66/6 |
| Connection | 5 core, PVC, unscreened |
| Weight | 500g |